



Single-phase nine-household fiberglass meter box
FRP meter box is made of SMC unsaturated polyester glass reinforced fiber molding. The FRP meter box has excellent performance of sealing waterproof performance, anti-corrosion performance, anti-electricity theft performance, beautiful appearance, and safety protection with locks and seals. The product is widely used in residential construction, civil electricity renovation and other projects.
Categories:
SMC Electric Meter Box
Application environmental conditions
Air temperature: the maximum temperature of the surrounding air does not exceed +60℃, and its average temperature does not exceed +35℃ within 24h. The lower limit of ambient air temperature is -25℃;
Pollution level: the pollution level does not exceed 2;
Altitude: not more than 2000m above sea level.
Installation place:
Metering box installation place conditions:
1, adapted to the wall, poles, floor and other installation places;
2, the external magnetic field: 5 times the geomagnetic field, any direction; use the location of the altitude ≤ 2000M;
3、Adapt to seismic intensity: 8 grade;
4, withstand the wind: 8 levels;
5、The inclination of the equipment to the vertical plane during installation is not more than 5%.
Citation standard
Q/GDW11008-2013 Technical specification for low voltage measuring box
GB/T 7251.1-2013 Low-voltage switchgear and controlgear Part 1: Type test and part of the type test sets of equipment
GB/T 7251.3-2017 Low-voltage switchgear and controlgear sets Part 3: Distribution boards (DBO) operated by general personnel
GB/T 7251.5-2017 Low-voltage switchgear and controlgear sets Part 5: Utility grid power distribution sets
GB/T 4208-2017 Enclosure protection level (IP code)
GB/T 9286-2021 Color paint and varnish Scratch test
Key words:
SMC Electric Meter Box
Get A Quote
Leave your contact information and get a free product quote
Solution
Become a leader in the power distribution industry in the intelligent era
Related Products
The company mainly operates transformer and distribution equipment such as screens, desks, cabinets, and boxes, as well as transformer and distribution equipment, transformers, switches, automation control systems, etc
● Model: SC(B)12、SC(B)14、SC(B)18 ● Capacity: 30kVA to 2500kVA ● Voltage: 0.4kV, 6kV to 11kV
10kV Three-dimensional Rolled Iron Core Transformer
● Voltage: 400V, 6kV to 10kV ● Capacity: 30kVA to 2500kVA ● Model: S13、S20、S22
10kV Amorphous Three-dimensional Rolled Iron Core Rransformer
● Voltage: 0.4kV, 6kV to 11kV ● Capacity: 30kVA to 2500kVA ● Model: SH25、SH21
0.4\6.6\10\11kV Cast Resin Dry Type Transformer
● Voltage: 0.4kV, 6kV to 11kV ● Capacity: 30kVA to 2500kVA ● Model: SC(B)12、SC(B)14、SC(B)18