10kV Distribution Transformer
10kV Distribution Transformer
10kV Distribution Transformer
10kV Distribution Transformer
10kV Distribution Transformer
10kV Distribution Transformer
+
  • 10kV Distribution Transformer
  • 10kV Distribution Transformer
  • 10kV Distribution Transformer
  • 10kV Distribution Transformer
  • 10kV Distribution Transformer
  • 10kV Distribution Transformer

10kV Distribution Transformer

● Voltage: 400V, 6kV to 10kV ● Capacity: 30kVA to 2500kVA ● Model: S13、S20、S22

Categories:

Oil-immersed Transformer

Product Overview

Oil-immersed three-dimensional rolled iron core transformer is a kind of high-efficiency energy-saving power transformer, using advanced three-dimensional rolled iron core technology, the core is assembled by three identical frames, silicon steel longitudinal shear through the set of cuts to achieve nearly 100% utilization, less corner remnants. Silicon steel sheet winding tight and no seams, high core filling coefficient, low magnetic resistance. Continuous winding can ensure that the direction of magnetic conduction of silicon steel is consistent with the actual magnetic flux direction. The three-phase magnetic circuit length of three-dimensional coiled core is the same, which can achieve three-phase magnetic circuit balance, no-load loss and no-load current are greatly reduced, and the noise is reduced by more than 10dB, which makes the product more widely used.

distribution transformer price

Application scenario

Model number

Rated

 capacity
(kVA)

 VoltageCombination

Linkage group

 labeling

Impedance voltage


(%)

Transformer weight
(t)

 size

(mm)
L*W*H

No-load loss
(w)

Load Loss
(w)

High Voltage(kV)

Low Voltage (kV)

S13-M.RL-30/10

30

6

6.3

10

10.5

0.4

Dyn11

YynO

4 

0.4

800*700*800

80

505/480

S13-M.RL-50/10

50

0.52

1000*850*950

100

730/695

S13-M.RL-63/10

63

0.58

1100*800*1200

110

870/830

S13-M.RL-80/10

80

0.65

1100*800*1350

130

1050/1000

S13-M.RL-100/10

100

0.72

1100*800*1350

150

1260/1200

S13-M.RL-125/10

125

0.78

1100*850*1400

170

1510/1440

S13-M.RL-160/10

160

0.9

1100*950*1420

200

1850/1760

S13-M.RL-200/10

200

1.1

1150*1000*1500

240

2180/2080

S13-M.RL-250/10

250

1.3

1200*1100*1500

290

2560/2440

S13-M.RL-315/10

315

1.7

1300*1120*1500

340

3060/2920

S13-M.RL-400/10

400

2.1

1350*1200*1550

410

3610/3440

S13-M.RL-500/10

500

2.6

1500*1300*1600

480

4330/4120

S13-M.RL-630/10

630

4.5

3.0

1500*1300*1700

570

4960

S13-M.RL-800/10

800

3.4

1550*1350*1750

700

6000

S13-M.RL-1000/10

1000

4.1

1750*1500*1750

830

8240

S13-M.RL-1250/10

1250

5.0

1800*1500*1900

970

9600

S13-M.RL-1600/10

1600

5.9

1900*1700*2000

1170

11600

S13 Three-dimensional rolled iron core series transformer

 

Model number

Rated

 capacity
(kVA)

 VoltageCombination

Linkage group

 labeling

Impedance voltage


(%)

Transformer weight
(t)

 size

(mm)
L*W*H

No-load loss
(w)

Load Loss
(w)

High Voltage(kV)

Low Voltage (kV)

S20-M.RL-30/10

30

6

6.3

10

10.5
0.4Dyn11

YynO
4 

0.4

800*700*800

70

505/480

S20-M.RL-50/10

50

0.57

1000*850*950

90

730/695

S20-M.RL-63/10

63

0.63

1100*800*1200

100

870/830

S20-M.RL-80/10

80

0.72

1100*800*1350

115

1050/1000

S20-M.RL-100/10

100

0.78

1100*800*1350

135

1260/1200

S20-M.RL-125/10

125

0.85

1100*850*1400

150

1510/1440

S20-M.RL-160/10

160

1.0

1100*950*1420

180

1850/1760

S20-M.RL-200/10

200

1.2

1150*1000*1500

215

2180/2080

S20-M.RL-250/10

250

1.4

1200*1100*1500

260

2560/2440

S20-M.RL-315/10

315

1.9

1300*1120*1500

305

3060/2920

S20-M.RL-400/10

400

2.3

1350*1200*1550

370

3610/3440

S20-M.RL-500/10

500

2.8

1500*1300*1600

430

4330/4120

S20-M.RL-630/10

630

4.5

3.3

1500*1300*1700

510

4960

S20-M.RL-800/10

800

3.7

1550*1350*1750

630

6000

S20-M.RL-1000/10

1000

4.5

1750*1500*1750

745

8240

S20M.RL-1250/10

1250

5.5

1800*1500*1900

870

9600

S20-M.RL-1600/10

1600

6.5

1900*1700*2000

1050

11600

S20 Three-dimensional rolled iron core series transformer

 

Model number

Rated

 capacity
(kVA)

 VoltageCombination

Linkage group

 labeling

Impedance voltage


(%)

Transformer weight
(t)

 size

(mm)
L*W*H

No-load loss
(w)

Load Loss
(w)

High Voltage(kV)

Low Voltage (kV)

S22-M.RL-30/10

30

6

6.3

10

10.5
0.4Dyn11

YynO

4

0.5

720*480*850

65

455/430

S22-M.RL-50/10

50

0.55

750*500*900

80

655/625

S22-M.RL-63/10

63

0.65

800*600*950

90

785/745

S22-M.RL-80/10

80

0.7

1000*720*980

105

945/900

S22-M.RL-100/10

100

0.8

1050*750*1000

120

1140/1080

S22-M.RL-125/10

125

0.95

1100*760*1050

135

1360/1295

S22-M.RL-160/10

160

1

1120*770*1070

160

1665/1585

S22-M.RL-200/10

200

1.1

1150*800*1100

190

1970/1870

S22-M.RL-250/10

250

1.3

1300*950*1100

230

2300/2195

S22-M.RL-315/10

315

1.55

1400*1000*1100

270

2760/2630

S22-M.RL-400/10

400

1.8

1400*1000*1200

330

3250/3095

S22-M.RL-500/10

500

2.65

1700*1200*1400

385

3900/3710

S22-M.RL-630/10

630

4.5

3.3

1800*1300*1500

460

4460

S22-M.RL-800/10

800

3.65

2150*1950*2000

560

5400

S22-M.RL-1000/10

1000

4.3

2200*2000*2050

665

7415

S22-M.RL-1250/10

1250

4.85

2300*2100*2100

780

8640

S22-M.RL-1600/10

1600

5.95

2400*2200*2200

940

10440

S22-M.RL-2000/10

2000

5

7.3

2500*2400*2300

1085

13180

S22-M.RL-2500/10

2500

8.5

2700*2600*2500

1280

13360

S22 Three-dimensional rolled iron core series transformer

Product Features

  • High efficiency and energy saving: adopting three-dimensional rolled iron core structure, the magnetic circuit is evenly distributed, reducing the seam loss of the traditional laminated iron core, the no-load loss and load loss are significantly reduced, and the energy efficiency level reaches the S20 standard and above, with obvious energy-saving effect.
  • Low-noise operation: The three-dimensional coiled iron core has fewer seams and less magnetic resistance, which drastically reduces vibration and noise during operation, making it suitable for noise-sensitive environments, such as residential areas, hospitals and schools.
  • Oil-immersed cooling: the use of mineral oil as a cooling and insulating medium, excellent heat dissipation performance, can effectively reduce the operating temperature of the transformer, suitable for long time high load operation, prolong the life of the equipment.
  • High reliability: optimized insulation and heat dissipation design, strong short-circuit resistance, stable and reliable operation, adapting to various complex working conditions and reducing the failure rate.
  • Environmentally friendly design: adopting environmentally friendly materials and processes, conforming to green manufacturing standards, reducing the impact on the environment, and meeting the requirements of modern power systems for environmental protection.
  • Compact structure: three-dimensional rolled iron core design makes the transformer small in size and light in weight, easy to transport and install, space saving, especially suitable for places with limited space.
  • Convenient maintenance: oil-immersed design facilitates internal inspection and maintenance, reduces operation and maintenance costs, and extends the service life of the transformer.
  • Strong short-circuit resistance: three-dimensional rolled iron core structure is solid, and the winding design is reasonable, which can withstand large short-circuit current impact and ensure the safe operation of the equipment.
  • Low temperature rise: The optimized design of oil-immersed cooling and three-dimensional rolled iron core makes the transformer run with low temperature rise, which improves the reliability and life of the equipment.
  • Strong adaptability: able to adapt to various complex environments and working conditions, such as high temperature, high humidity, high altitude, etc. It is widely used in scenarios such as power systems, industrial and mining enterprises, urban power grids and rural power grids.
  • Good economy: Although the initial investment is high, the long-term operation economy is remarkable and the overall cost is low due to its high energy efficiency and low maintenance cost.
  • Intelligent optional: Intelligent monitoring system can be integrated to monitor current, voltage, temperature and other parameters in real time, support remote control and fault diagnosis, and improve operation and maintenance efficiency.

Application scenario

Oil-immersed stacked core transformers are suitable for the following scenarios:

  • Used as a voltage booster or voltage reducer in power systems
  • Power distribution and transmission in industry
  • Power supply and backup power in commercial buildings
  • Other locations requiring a stable and reliable power supply

Transformer Workshop

Transformer Manufacturer

Key words:

Oil-immersed Transformer

transformer

Three-phase transformers

Three-dimensional Rolled Iron Core Transformer

Get A Quote

Leave your contact information and get a free product quote

Solution

Become a leader in the power distribution industry in the intelligent era

Related Products

The company mainly operates transformer and distribution equipment such as screens, desks, cabinets, and boxes, as well as transformer and distribution equipment, transformers, switches, automation control systems, etc

1000kVA Oil-immersed Transformer


● Voltage: 6kV to 11kV ● Capacity: 30kVA to 2500kVA

10kV Distribution Transformer


● Voltage: 400V, 6kV to 10kV ● Capacity: 30kVA to 2500kVA ● Model: S13、S20、S22

1250kVA Epoxy Resin Cast Dry Type Transformer


● Voltage: 10kV ● Capacity: 30kVA to 2500kVA ● Model: SC(B)10

500kVA Three Phase Oil Immersed Transformer 10kV


● Voltage: 400V/10kV ● Capacity: 30kVA to 2500kVA

Get A Quote

Leave your contact information and get a free product quote