PC+ABS Electricity meter box
+
  • PC+ABS Electricity meter box

PC+ABS Electricity meter box

PC + ABS meter box as a whole mainly uses polycarbonate and acrylonitrile-butadiene-styrene copolymer engineering plastics (PC + ABS) injection molding, the box has insulation, high temperature, aging resistance, impact resistance, anti-corrosion, moisture-proof, waterproof, safe and reliable, the electricity metering device adopts a fully closed management, with closed metering circuit, preventing electricity theft, easy to read the meter and other functions.

Categories:

PC+ABS Electricity meter box

Technical Parameters
Main busbar rated current In:225A˜10A Main busbar rated short-time withstand current Icw:35KA
Insulation resistance: not less than 20㏁ Rated insulation voltage UI: 880V
Frequency: 50Hz or 60Hz Safety Protection Grade IP: 35

Application environmental conditions
Air temperature: The maximum ambient air temperature does not exceed +60℃, and its average temperature does not exceed +35℃ within 24h. The lower limit of ambient air temperature is -25℃;
Pollution level: the pollution level does not exceed 2; 
Altitude: not more than 2000m above sea level.
Installation place:
Metering box installation place conditions:
1, adapted to wall, pole, floor and other installation places;
2, the external magnetic field: 5 times the geomagnetic field, any direction; use the location of the altitude ≤ 2000M;
3、Adapt to seismic intensity: 8 grade;
4, withstand the wind: 8 levels;
5、The inclination of the equipment to the vertical plane during installation is not more than 5%.

Citation standard
Q/GDW11008-2013 Technical specification for low voltage measuring box
GB/T 7251.1-2013 Low-voltage switchgear and controlgear Part 1: Type test and part of the type test sets of equipment
GB/T 7251.3-2017 Low-voltage switchgear and controlgear sets Part 3: Distribution boards (DBO) operated by general personnel
GB/T 7251.5-2017 Low-voltage switchgear and controlgear sets Part 5: Utility grid power distribution sets
GB/T 4208-2017 Enclosure protection level (IP code)
GB/T 9286-2021 Color paint and varnish scratch test
GB/T 9341-2008 Plastics Determination of bending properties

Key words:

Electricity meter box

Get A Quote

Leave your contact information and get a free product quote

Solution

Become a leader in the power distribution industry in the intelligent era

Related Products

The company mainly operates transformer and distribution equipment such as screens, desks, cabinets, and boxes, as well as transformer and distribution equipment, transformers, switches, automation control systems, etc

10kV Dry-type Transformer


● Model: SC(B)12、SC(B)14、SC(B)18 ● Capacity: 30kVA to 2500kVA ● Voltage: 0.4kV, 6kV to 11kV

10kV Three-dimensional Rolled Iron Core Transformer


● Voltage: 400V, 6kV to 10kV ● Capacity: 30kVA to 2500kVA ● Model: S13、S20、S22

10kV Amorphous Three-dimensional Rolled Iron Core Rransformer


● Voltage: 0.4kV, 6kV to 11kV ● Capacity: 30kVA to 2500kVA ● Model: SH25、SH21

0.4\6.6\10\11kV Cast Resin Dry Type Transformer


● Voltage: 0.4kV, 6kV to 11kV ● Capacity: 30kVA to 2500kVA ● Model: SC(B)12、SC(B)14、SC(B)18

Get A Quote

Leave your contact information and get a free product quote