XGW-12 outdoor box-type fixed opening and closing, also known as ring network box, will be 10kV environmentally friendly gas ring network cabinets, current transformers, voltage transformers, automation station terminals (DTU) and indicating instruments, etc., installed and commissioned into a movable, sealed, moisture-proof and anti-condensation non-metallic GRC or stainless steel box, which realizes the integration of the primary and secondary systems in the urban power distribution network, shortens the construction period, and greatly improves the reliability of urban power grid operation. Construction cycle, greatly improving the reliability of urban power grid operation.

Categories:

Ring Main Unit

Product Overview 
XGW-12 outdoor box-type fixed opening and closing, also known as ring network box, will be 10kV environmentally friendly gas ring network cabinets, current transformers, voltage transformers, automation station terminals (DTU) and indicating instruments, etc., installed and commissioned into a movable, sealed, moisture-proof and anti-condensation non-metallic GRC or stainless steel box, which realizes the integration of the primary and secondary systems in the urban power distribution network, shortens the construction period, and greatly improves the reliability of urban power grid operation. Construction cycle, greatly improving the reliability of urban power grid operation.

The performance index of XGW□-12 outdoor box-type stationary switchgear reaches the requirements of GB/T17467 “High-voltage/low-voltage preassembled substation” and IEC466: “AC insulated enclosed switchgear and controlgear with a rated voltage of more than 1kV and less than 38kV”.

Functional features
1. Adopting prefabricated electrically charged touchable silicone rubber cable head, fully sealed, fully insulated, maintenance-free, and reliably guaranteeing personal safety;

2. Compact structure, small and beautiful appearance, stainless steel double-layer box, the service life can be more than twenty years;

3. Without affecting the operation of the main network, it can realize regional power outage maintenance and reduce the scope of power outage;

4. The box material all adopts the surface spraying of aluminum zinc steel plate or stainless steel plate, the thickness is not less than 2mm, has a strong corrosion resistance, in addition to the main cabinet frame, other box parts are sheet metal components, light weight, beautiful and generous;

5. No fasteners on the surface of the box can be disassembled, good anti-theft, the box has IP3X protection level, good rain performance;

6. The top cover is air sandwich double-layer structure, and is equipped with vents; air inlet is located at the surface plate of the box, and there is a removable dust filter; air outlet is located at the top of the box, and is hidden under the eaves; the formation of air convection from the bottom up, so that the box has a good thermal insulation and ventilation effect.

Technical Parameters
Rated voltage: 12kV

Rated current: 630A

Frequency withstand voltage (phase ground): 42k V/min

Lightning impact voltage: 75kV

Rated breaking current: 630A

Rated short-circuit opening and closing current (peak): 50kA

Rated short-circuit withstand current:25/4 kA/S

Rated peak withstand current: 50kA

Application environmental conditions

Air temperature: Maximum ambient air temperature not exceeding +40℃, lower limit of ambient air temperature is -40℃;

Altitude: conventionally not exceeding 1000m;

Wind pressure: not exceeding 700Pa (wind speed not exceeding 34m/s);

Pollution level: Class IV; 

Thickness of ice cover: 20mm

Humidity: the average daily value of relative humidity is not more than 95%, and the average monthly value is not more than 90%;

Seismic capacity: geomorphic horizontal acceleration 3.0 m/s2.

The installation location is free from fire, explosion danger, chemical corrosion and severe vibration.

Key words:

10KV ring box

Get A Quote

Leave your contact information and get a free product quote

Solution

Become a leader in the power distribution industry in the intelligent era

Related Products

The company mainly operates transformer and distribution equipment such as screens, desks, cabinets, and boxes, as well as transformer and distribution equipment, transformers, switches, automation control systems, etc

测试


● Voltage: 6kV to 11kV ● Capacity: 30kVA to 2500kVA

10kV Dry-type Transformer


● Model: SC(B)12、SC(B)14、SC(B)18 ● Capacity: 30kVA to 2500kVA ● Voltage: 0.4kV, 6kV to 11kV

6.6\11kV Oil-immersed Transformer


● Voltage: 6kV to 11kV ● Capacity: 30kVA to 2500kVA

10kV Three-dimensional Rolled Iron Core Transformer


● Voltage: 400V, 6kV to 10kV ● Capacity: 30kVA to 2500kVA ● Model: S13、S20、S22