XGN-12 series fully insulated and sealed environmentally friendly gas insulated ring network cabinet
+
  • XGN-12 series fully insulated and sealed environmentally friendly gas insulated ring network cabinet

XGN-12 series fully insulated and sealed environmentally friendly gas insulated ring network cabinet

XGN-12 fully-insulated and fully-enclosed gas-insulated ring network cabinet is widely used in 10kV/6kV power distribution system, and is the switchgear product of choice for all kinds of urban and rural users' power distribution system.

Categories:

High And Low Voltage Switchgear

Product Overview
XGN-12 fully-insulated and fully-enclosed gas-insulated ring network cabinet is widely used in 10kV/6kV power distribution system, and is the switchgear product of choice for all kinds of urban and rural users' power distribution system. The switchgear is modularized unit mode, which can be combined according to different purposes; it consists of two categories: fixed unit combination and expandable unit, which meets the needs of various substations for flexible use of compact switchgear. The XGN-12 fully insulated and enclosed gas ring main unit is a completely sealed system, with its electrically charged parts and switches enclosed in stainless steel body. The entire switchgear is not affected by external environmental conditions, thus ensuring operational reliability and personal safety. It is also maintenance-free. By selecting an extendable busbar, any combination can be realized and full modularity is achieved. The safety insulation and shielding of the extension busbar ensures reliability and safety.XGN□-12 fully insulated inflatable ring switchgear can also provide TV-based automation solutions, forming the concept of intelligent switchgear and greatly reducing the workload of on-site installation and commissioning. XGN□-12 fully insulated and fully enclosed gas ring main unit is divided into non-expandable standard configuration and expandable standard configuration. The combination of full-module and half-module as well as self-expandability provides exceptional flexibility. XGN□-12 fully-insulated and fully-closed gas ring main unit executes GB standard. The design life for operation under indoor conditions (20℃) is more than 30 years.

Model and meaning
XGN□-12(V)/T630-20

X-box type

G-Fixed type

N-Indoor

12-Rated voltage (kV)

V-Cabinet type name:

C : Load switch cabinet; F : Fuse combination cabinet; V : Vacuum circuit breaker cabinet;

SV, SL, busbar segmentation cabinet; M : measurement cabinet; PT : PT cabinet ( common box cabinet by C, F, V, SV, SL any combination.)

T-spring operating mechanism

630-Main busbar rated current (A)

20-Rated short-circuit breaking current (kA)

Product characteristics
1、Structural composition

The switchgear shell is assembled by spraying aluminum-zinc-decorated plate or common steel plate. It mainly consists of busbar room, main switch, cable room, operating mechanism, interlocking mechanism and low voltage control room.

2、Bus room

Busbar room is located in the upper part of the switchgear. In the system, the main busbar runs through the busbar room and completes the connection in the busbar room. The main busbar is horizontally arranged and can be easily expanded.

3、Main switch room

a) Load switch room: The switch room is equipped with three-position load switches, whose shells are made of epoxy resin, insulated and arc-extinguished with SF6 gas, and have the following functions: “close”; “split”; “ground”; three-position load switches; and three-position load switches with the following functions: “close”; “split”; “ground”; and “ground”. ”; three-station arc extinguishing chamber, reliable interlocking, high insulation strength of the fracture, large creepage distance design. SF6 gas pressure gauge is installed at obvious position for monitoring during operation.

b) Circuit breaker room: the circuit breaker room is located in the middle of the cabinet, which can be assembled with special vacuum circuit breakers or SF6 circuit breakers according to the user's needs. The ring network cabinet with circuit breakers is mainly used in the ring network power supply system as the inlet cabinet of main power supply and standby power supply as well as the intermediate sectional cabinet of dual power supply system.

4、Cable Room

The cable room is mainly used for cable connection, single-core or three-core cables can be connected by the simplest unshielded cable head. At the same time, the cable room has enough space to accommodate current transformers, surge arresters, lower grounding switches and other components. In accordance with the standard design, the cabinet door is also designed with an observation window and a safety interlocking device. The bottom plate of the cable room and the front door frame can be removed for easy cable installation. The bottom plate of cable room is equipped with rubber sealing cover and cable fixing clip.

5、Operating mechanism, interlocking mechanism and low voltage control room

The interlocked low voltage room also serves as a control panel. The low voltage room is equipped with spring operating mechanism with position indicator and mechanical interlocking device, auxiliary contact, trip coil, emergency trip mechanism, capacitive charged display, key lock and electric operating device can also be installed, and at the same time, the space of the low voltage room can also be equipped with control circuits, metering instrumentation and protection relays, 750mm wide cabinet has two identical low voltage rooms, which can be equipped with more accessories.

The whole XGN switchgear cabinet can be divided into upper and lower units. The upper unit of the cabinet includes busbar room, load switch, operating mechanism and low voltage room, which can be assembled with the cable room of the lower unit to form a whole cabinet, or can be separated. The equipment installed in the upper unit can be safely and conveniently overhauled and remodeled, and the entire upper unit can be replaced.

operating conditions
Surrounding air temperature: - 15 ℃ ~ +40 ℃; altitude: not more than 1000m; relative humidity: daily average relative humidity is not greater than 95%, the average daily value of water vapor pressure does not exceed 2.2kPa; monthly average relative humidity is not greater than 90%, the average daily value of water vapor pressure does not exceed 1.8kPa; seismic intensity: not more than 8 degrees; corrosive, no violent vibration and impact, explosion risky places. Place;

Note: beyond the above normal conditions of use, the user can negotiate with the company to solve.

Main technical parameters

Key words:

Environmentally friendly gas insulated ring network switchgear

Get A Quote

Leave your contact information and get a free product quote

Solution

Become a leader in the power distribution industry in the intelligent era

Related Products

The company mainly operates transformer and distribution equipment such as screens, desks, cabinets, and boxes, as well as transformer and distribution equipment, transformers, switches, automation control systems, etc

测试


● Voltage: 6kV to 11kV ● Capacity: 30kVA to 2500kVA

10kV Dry-type Transformer


● Model: SC(B)12、SC(B)14、SC(B)18 ● Capacity: 30kVA to 2500kVA ● Voltage: 0.4kV, 6kV to 11kV

6.6\11kV Oil-immersed Transformer


● Voltage: 6kV to 11kV ● Capacity: 30kVA to 2500kVA

10kV Three-dimensional Rolled Iron Core Transformer


● Voltage: 400V, 6kV to 10kV ● Capacity: 30kVA to 2500kVA ● Model: S13、S20、S22

Get A Quote

Leave your contact information and get a free product quote