● Material: stainless steel ● Product features: Good sealing, anti-corrosion and anti-rust, sturdy and durable

Categories:

Photovoltaic Combiner Box

Product Function
This product is mainly used between the AC output side of the inverter of distributed power generation system and the load of the grid-connected point, with the functions of power measurement, short-circuit protection, loss-of-voltage protection, lightning protection, switching protection, over-current protection, for the measurement and control management of three-phase power and power isolation.

Scope of application
PV grid-connected box is a device to converge the AC power from inverter to the grid or user side. This product includes metering and distribution of two parts of the reserved metering meter and collector installation position, the capacity covers 10KW-60KW, the product has isolation protection, overload protection, short circuit protection, surge protection, over-under-voltage protection and after the recovery of the reclosing, power generation metering and other functions. (According to customer requirements to increase the relevant functions, etc.)

Product features

  1. Wall-mounted sealed product with protection level up to IP65, which can meet the requirements of outdoor installation;
  2. Strict high and low temperature testing, applicable to a wide range of regions;
  3. Cabinet materials are available in stainless steel, cold rolled steel, galvanized plate, sturdy and durable;
  4. Selection of PV-specific pull-ring disconnect switches, safer operation;
  5. Selection of PV-specific grid-connected circuit breakers; bi-directional billing, to meet a variety of users;
  6. Simple installation, simplified system wiring, convenient wiring;
  7. Unique ventilation holes design, reduce the temperature inside the box, delay the service life of the product.
  8. Anti-islanding device can be configured according to customer requirements
  9. (Product interior diagram, components or internal structure explanation)

Technical Parameters

Basic Parameters

Number of inverter input channels

1

Number of output channels

1

Rated AC voltage

220V/230V/240V/400V

Maximum rated input current 

32A/50A/63A/100A/125A

Rated frequency

50HZ/60HZ

Energy Meter Access

Direct access/secondary access

Enclosure

Case material

Cold rolled steel/stainless steel

Protection class

IP65

Impact protection grade

IK10

Dimension 

Customized

Inverter access port 

M50(32.7~38mm)

Grid access port 

M50(32.7~38mm)

Disconnect Switch

Rated voltage(AC)

230V/400V

Rated Current(AC) 

63A/100A/160A/200A/400A

Type

Single throw switch

Over-under-voltage protector

Breaker Type

2P/4P

Rated voltage(AC)

230V/400V

Maximum Current(AC)

63A/80A/125A/250A

Overvoltage protection value (phase voltage)

≥290V/253~300V

Undervoltage protection value (phase voltage)

≤150V/154~187V

Undervoltage protection value (phase voltage)

<45V

Rated frequency

50HZ/60HZ

AC Surge Protector

Maximum working voltage(AC)

230V/400V

Maximum Discharge Current(AC)

40KA

AC Circuit Breaker

Breaker Type

2P/4P

Rated voltage(AC)

400V

Rated current(AC) 

32A/60A/63A/80A/100A/125A/250A

Rated frequency 

50HZ/60HZ

Environmental parameters

Operating temperature

﹣20℃—﹢60℃

Working Humidity

99%

Altitude

2000m

Installation

Wall mounting

Key words:

Photovoltaic Grid Box

Get A Quote

Leave your contact information and get a free product quote

Solution

Become a leader in the power distribution industry in the intelligent era

Related Products

The company mainly operates transformer and distribution equipment such as screens, desks, cabinets, and boxes, as well as transformer and distribution equipment, transformers, switches, automation control systems, etc

测试


● Voltage: 6kV to 11kV ● Capacity: 30kVA to 2500kVA

10kV Dry-type Transformer


● Model: SC(B)12、SC(B)14、SC(B)18 ● Capacity: 30kVA to 2500kVA ● Voltage: 0.4kV, 6kV to 11kV

6.6\11kV Oil-immersed Transformer


● Voltage: 6kV to 11kV ● Capacity: 30kVA to 2500kVA

10kV Three-dimensional Rolled Iron Core Transformer


● Voltage: 400V, 6kV to 10kV ● Capacity: 30kVA to 2500kVA ● Model: S13、S20、S22