Integrated distribution box
JP comprehensive distribution box is a kind of outdoor comprehensive distribution point device integrating power distribution, metering, protection, control and reactive power compensation, with the protection functions of short-circuit, overload, over-voltage, leakage, etc. It is small in size, beautiful in appearance, economical and practical, and it is installed on the outdoor pole of column transformer, and it is a new generation of ideal distribution products for the urban and rural power grid reconstruction.
Categories:
Distribution Box
Technical Parameters
Rated voltage: 380VAC; Rated insulation voltage: 690VAC.
Rated frequency: 50HZ or 60HZ.
Compensation mode: combination of three-phase compensation and single-phase compensation.
Compensation capacity: 30kvar~120kvar.
Compensation mode: cyclic casting, coded casting, fuzzy control automatic casting.
Faster response time: ≤20ms
Use conditions
1,Surrounding air temperature: upper limit +40°C, lower limit -30°C
2,Wind speed: quite 34m/s (not greater than 700Pa)
3, relative humidity daily average is not greater than 95% (+25 ° C), monthly average is not greater than 90% (+25 ° C)
4, the surrounding air should not be corrosive, flammable gases, water vapor and other obvious pollution
5, earthquake intensity does not exceed 8 °
6,No regular severe vibration
Citation standards
GB 4208 shell protection level (IP code)
GB/T 5585 copper, aluminum and its alloy busbar for electricians
GB/Z 6829 residual current action protection appliances general requirements
GB 7251.1 Low-voltage switchgear and controlgear Part 1: General provisions
GB/T10233 Basic test methods for low-voltage switchgear and electronic control equipment
GB13955 Installation and operation of residual current action protection devices
GB14048.2 Low-voltage switchgear and controlgear Part 2: Circuit breakers
GB/T15576 Low-voltage complete sets of reactive power compensation devices
GB/T 16935.1 Insulation fit of equipment in low voltage systems Part 1: Principles, requirements and tests
GB 50171 Specification for construction and acceptance of mounted electrical installations and panels, cabinets and secondary circuit wiring
DL/T375 General technical conditions for outdoor distribution boxes
DL/T499 Rural low-voltage power technical regulations
DL/T614 Multi-function Power Meter
Q/GDW11196 Technical Principles for Selection and Testing of Residual Current Action Protectors
Key words:
Integrated distribution box
Get A Quote
Leave your contact information and get a free product quote
Solution
Become a leader in the power distribution industry in the intelligent era
Related Products
The company mainly operates transformer and distribution equipment such as screens, desks, cabinets, and boxes, as well as transformer and distribution equipment, transformers, switches, automation control systems, etc
● Model: SC(B)12、SC(B)14、SC(B)18 ● Capacity: 30kVA to 2500kVA ● Voltage: 0.4kV, 6kV to 11kV
10kV Three-dimensional Rolled Iron Core Transformer
● Voltage: 400V, 6kV to 10kV ● Capacity: 30kVA to 2500kVA ● Model: S13、S20、S22
0.4\6.6\10\11kV Cast Resin Dry Type Transformer
● Voltage: 0.4kV, 6kV to 11kV ● Capacity: 30kVA to 2500kVA ● Model: SC(B)12、SC(B)14、SC(B)18






