10kV pole mounted transformer set
The complete set of 10kV column station equipment is revised by the State Grid for the implementation of the requirements of the procurement work of 10kV column station complete set.
Categories:
Iot Switch
Product Description
The complete set of 10kV column station equipment is revised by the State Grid for the implementation of the requirements of the procurement work of 10kV column station complete set, further deepen and improve the typical design of distribution network engineering, and the State Grid Operation and Inspection Department on the basis of in-depth research and extensive consultation, and the organization of the revision. The company through the research and introduction of a new one-piece combination of compensation module, completely replaced the old composite switch + capacitor switching method, not only reduces the company's production costs, but also improves the production efficiency, so that the company in the State Grid bidding, more than a share of the advantage.
Technical parameters and application environment conditions
System voltage: 10kV on the high voltage side / 0.4kV on the low voltage side
System nominal voltage: 10kV;
Maximum operating voltage: 12kV;
Rated capacity: 50~400kVA
Compensation capacity: 30~200kvar
Rated frequency: 50Hz;
Filth level: e class;
Installation mode: ZA-1-CX, ZA-1-ZX, ZA-1-CL
Ambient temperature: Maximum daily temperature not exceeding +45℃, lower limit of daily temperature -25℃, maximum daily temperature difference 25, hottest monthly average temperature 30℃, maximum annual average temperature 20℃ (or provided by the customer);
Ice cover thickness: 20mm;
Altitude: no more than 1000m above sea level;
Solar radiation intensity: 0.1W/cm2;
Seismic tolerance: geomorphic horizontal acceleration 3 m/s2; sinusoidal resonance 3 cycles safety coefficient not less than 1.67;
The average maximum wind speed of 35m/s maintained for 10min at a height of 10m above the ground.
Key words:
10kV pole mounted transformer set
Get A Quote
Leave your contact information and get a free product quote
Solution
Become a leader in the power distribution industry in the intelligent era
Related Products
The company mainly operates transformer and distribution equipment such as screens, desks, cabinets, and boxes, as well as transformer and distribution equipment, transformers, switches, automation control systems, etc
● Model: SC(B)12、SC(B)14、SC(B)18 ● Capacity: 30kVA to 2500kVA ● Voltage: 0.4kV, 6kV to 11kV
10kV Three-dimensional Rolled Iron Core Transformer
● Voltage: 400V, 6kV to 10kV ● Capacity: 30kVA to 2500kVA ● Model: S13、S20、S22
0.4\6.6\10\11kV Cast Resin Dry Type Transformer
● Voltage: 0.4kV, 6kV to 11kV ● Capacity: 30kVA to 2500kVA ● Model: SC(B)12、SC(B)14、SC(B)18