10kV  Amorphous Three-dimensional Rolled Iron Core Rransformer
10kV  Amorphous Three-dimensional Rolled Iron Core Rransformer
10kV  Amorphous Three-dimensional Rolled Iron Core Rransformer
10kV  Amorphous Three-dimensional Rolled Iron Core Rransformer
+
  • 10kV  Amorphous Three-dimensional Rolled Iron Core Rransformer
  • 10kV  Amorphous Three-dimensional Rolled Iron Core Rransformer
  • 10kV  Amorphous Three-dimensional Rolled Iron Core Rransformer
  • 10kV  Amorphous Three-dimensional Rolled Iron Core Rransformer

10kV Amorphous Three-dimensional Rolled Iron Core Rransformer

● Voltage: 0.4kV, 6kV to 11kV ● Capacity: 30kVA to 2500kVA ● Model: SH25、SH21

Categories:

Oil-immersed Transformer

Product Overview

New energy-efficient amorphous alloy transformer, is a new generation of energy-saving and environmentally friendly transformers, amorphous alloy processed using rapid rapid cold solidification production process, the physical state of the performance of the metal atoms in a disordered amorphous arrangement, which is completely different from the crystalline structure of silicon steel, more conducive to be magnetized and demagnetized, this new type of material used in transformer cores, which can significantly reduce the no-load loss of the iron core, known as the new century's This new material used in transformer core can greatly reduce the no-load loss of the core, known as the new century's "green material", is widely used in the agricultural network and other low load level of the region, is to realize the transmission and distribution network energy saving and emission reduction of one of the important equipment.

Application scenario

Model number

Rated capacity
(kVA)

 VoltageCombination

Linkage group

 labeling

Impedance voltage


(%)

 weight
(kg)

 reference size

(mm)
L*W*H

No-load loss
(w)

Load Loss
(w)

High Voltage(kV)

Low Voltage (kV)

SH25-M.RL-30/10

30

6

6.3

10

10.5

0.4

Dyn11

YynO

0.45

1000*550*700

25

510/480

SH25-M.RL-50/10

50

0.6

1100*600*700

35

735/700

SH25-M.RL-63/10

63

0.65

1100*650*900

40

880/840

SH25-M.RL-80/10

80

0.75

1150*650*900

50

1060/1010

SH25-M.RL-100/10

100

0.85

1200*700*900

60

1270/1215

SH25-M.RL-125/10

125

0.95

1250*950*900

70

1530/1450

SH25-M.RL-160/10

160

1.0

1300*1100*900

80

1870/1780

SH25-M.RL-200/10

200

1.26

1400*1000*900

95

2210/2100

SH25-M.RL-250/10

250

1.5

1600*1100*950

110

2590/2470

SH25-M.RL-315/10

315

1.7

1700*1100*970

135

3100/2950

SH25-M.RL-400/10

400

1.94

1750*1100*1000

160

3660/3480

SH25-M.RL-500/10

500

2.2

1800*1100*1100

190

4380/4170

SH25-M.RL-630/10

630

4.5

2.53

1900*1100*1100

250

5020

SH25-M.RL-800/10

800

3.0

2000*1500*1200

300

6075

SH25-M.RL-1000/10

1000

3.6

2100*1600*1350

360

8340

SH25-M.RL-1250/10

1250

4.3

2200*1700*1350

425

9720

SH25-M.RL-1600/10

1600

5.3

2300*1900*1400

500

11745

11kV(10.5kV/10kV/6.3kV/6kV)  SH25  Amorphous Three-dimensional Rolled Iron Core Rransformer

 

Model number

Rated capacity
(kVA)

 VoltageCombination

Linkage group

 labeling

Impedance voltage


(%)

 weight
(kg)

 reference size

(mm)
L*W*H

No-load loss
(w)

Load Loss
(w)

High Voltage(kV)

Low Voltage (kV)

SH21-M.RL-30/10

30

6

6.3

10

10.5

0.4

Dyn11

YynO

0.45

1000*550*700

25

510/480

SH21-M.RL-50/10

50

0.6

1100*600*700

35

735/700

SH21-M.RL-63/10

63

0.65

1100*650*900

40

880/840

SH21-M.RL-80/10

80

0.75

1150*650*900

50

1060/1010

SH21-M.RL-100/10

100

0.85

1200*700*900

60

1270/1215

SH21-M.RL-125/10

125

0.95

1250*950*900

70

1530/1450

SH21-M.RL-160/10

160

1.0

1300*1100*900

80

1870/1780

SH21-M.RL-200/10

200

1.26

1400*1000*900

95

2210/2100

SH21-M.RL-250/10

250

1.5

1600*1100*950

110

2590/2470

SH21-M.RL-315/10

315

1.7

1700*1100*970

135

3100/2950

SH21-M.RL-400/10

400

1.94

1750*1100*1000

160

3660/3480

SH21-M.RL-500/10

500

2.2

1800*1100*1100

190

4380/4170

SH21-M.RL-630/10

630

4.5

2.53

1900*1100*1100

250

5020

SH21-M.RL-800/10

800

3.0

2000*1500*1200

300

6075

SH21-M.RL-1000/10

1000

3.6

2100*1600*1350

360

8340

SH21-M.RL-1250/10

1250

4.3

2200*1700*1350

425

9720

SH21-M.RL-1600/10

1600

5.3

2300*1900*1400

500

11745

11kV(10.5kV/10kV/6.3kV/6kV)  SH21  Amorphous Three-dimensional Rolled Iron Core Rransformer

 

Product Features

  • High efficiency performance: amorphous alloy oil-immersed transformer has high energy conversion efficiency, can provide more stable and reliable power output. With very low hysteresis loss and eddy current loss, no-load loss is 60%-80% lower than the traditional silicon steel sheet transformer, the energy efficiency level reaches the first grade energy efficiency standards, energy saving effect is remarkable.
  • Low noise: amorphous alloy oil-immersed transformer core magnetostriction effect is small, low vibration and noise during operation, can reduce environmental pollution and noise impact on people, providing a quieter working and living environment.
  • High reliability: the use of high-quality amorphous alloy materials and advanced manufacturing process, the transformer structure is solid, strong short-circuit resistance, stable and reliable operation.
  • Environmental protection design: amorphous alloy material production energy consumption is low, and transformer operation process loss is small, reduce carbon emissions, in line with green environmental protection requirements.
  • Small volume, light weight: amorphous alloy core has high magnetic permeability, the volume and weight of the transformer under the same capacity is smaller than the traditional transformer, which is convenient for transportation and installation.
  • Strong overload resistance: amorphous alloy transformer has a good overload capacity, can withstand a large overload current in a short period of time, to ensure the safe operation of equipment.
  • Low temperature rise: amorphous alloy core loss is low, heat generation is small, transformer operation temperature rise is low, improve the reliability and life of the equipment.
  • Strong adaptability: able to adapt to a variety of complex environments and working conditions, such as high temperature, high humidity, high altitude and other scenarios.
  • Intelligent optional: Intelligent monitoring system can be integrated to monitor current, voltage, temperature and other parameters in real time, support remote control and fault diagnosis, and improve operation and maintenance efficiency.
  • Futurization: with the continuous progress of amorphous alloy material technology and cost reduction, amorphous alloy transformer will be more widely used in the future, and become an important choice for energy-saving transformation of the power system.

Application scenario

Oil-immersed amorphous alloy three-dimensional rolled-core transformers are suitable for the following scenarios:

  • Used as a voltage booster or voltage reducer in power systems
  • Power distribution and transmission in industry
  • Power supply and backup power in commercial buildings
  • Other locations requiring a stable and reliable power supply

Transformer Workshop

Key words:

Get A Quote

Leave your contact information and get a free product quote

Solution

Become a leader in the power distribution industry in the intelligent era

Related Products

The company mainly operates transformer and distribution equipment such as screens, desks, cabinets, and boxes, as well as transformer and distribution equipment, transformers, switches, automation control systems, etc

10kV Dry-type Transformer


● Model: SC(B)12、SC(B)14、SC(B)18 ● Capacity: 30kVA to 2500kVA ● Voltage: 0.4kV, 6kV to 11kV

6.6\11kV Oil-immersed Transformer


● Voltage: 6kV to 11kV ● Capacity: 30kVA to 2500kVA

10kV Three-dimensional Rolled Iron Core Transformer


● Voltage: 400V, 6kV to 10kV ● Capacity: 30kVA to 2500kVA ● Model: S13、S20、S22

0.4\6.6\10\11kV Cast Resin Dry Type Transformer


● Voltage: 0.4kV, 6kV to 11kV ● Capacity: 30kVA to 2500kVA ● Model: SC(B)12、SC(B)14、SC(B)18

Get A Quote

Leave your contact information and get a free product quote