10KV ring box
One or two times fusion ring network box is an intelligent complete set of equipment launched with the requirements of “Technical Standard for One or Two Times Complete Set of Equipment for Power Distribution”.
Categories:
Compact Substation
Product Overview
One or two times fusion ring network box is an intelligent complete set of equipment launched with the requirements of “Technical Standard for One or Two Times Complete Set of Equipment for Power Distribution”, which integrates the characteristics of power distribution network in each region of China and the actual situation of urban power distribution cable transformation. It consists of ring-in-ring-out unit, feeder unit, busbar equipment (PT) unit, centralized DTU and connecting cable. It is capable of collecting active power, reactive power, power factor, frequency, zero sequence current and zero sequence voltage, with line loss measurement, power measurement function, as well as line voltage identification, voltage overrun, load overrun and other alarm uploading, short-circuit fault detection and processing, single-phase grounding fault detection and processing, supporting short-circuit/grounding fault event uploading to meet the needs of distribution network automation.
Technical parameters and application environment conditions
Rated voltage: 12V
Rated current: 630A
Industrial frequency withstand voltage (phase ground): 42k V/min
Lightning impulse voltage: 74kV
Rated breaking current: 630A
Rated short-circuit opening and closing current (peak): 50kA
Rated short-circuit withstand current:25/4 kA/S
Rated peak withstand current: 50kA
Air temperature: the maximum surrounding air temperature does not exceed +40℃, the lower limit of surrounding air temperature is -40℃;
Pollution level: Class IV;
Ice cover thickness: 20mm
Humidity: the average daily value of relative humidity is not more than 95%, and the average monthly value is not more than 90%;
Seismic capacity: geomorphic horizontal acceleration 3.0 m/s2.
Key words:
10KV ring box
Get A Quote
Leave your contact information and get a free product quote
Solution
Become a leader in the power distribution industry in the intelligent era
Related Products
The company mainly operates transformer and distribution equipment such as screens, desks, cabinets, and boxes, as well as transformer and distribution equipment, transformers, switches, automation control systems, etc
● Model: SC(B)12、SC(B)14、SC(B)18 ● Capacity: 30kVA to 2500kVA ● Voltage: 0.4kV, 6kV to 11kV
10kV Three-dimensional Rolled Iron Core Transformer
● Voltage: 400V, 6kV to 10kV ● Capacity: 30kVA to 2500kVA ● Model: S13、S20、S22
10kV Amorphous Three-dimensional Rolled Iron Core Rransformer
● Voltage: 0.4kV, 6kV to 11kV ● Capacity: 30kVA to 2500kVA ● Model: SH25、SH21
0.4\6.6\10\11kV Cast Resin Dry Type Transformer
● Voltage: 0.4kV, 6kV to 11kV ● Capacity: 30kVA to 2500kVA ● Model: SC(B)12、SC(B)14、SC(B)18