SMC Cable Branch Box
SMC Cable Branch Box
SMC Cable Branch Box
+
  • SMC Cable Branch Box
  • SMC Cable Branch Box
  • SMC Cable Branch Box

SMC Cable Branch Box

● Material: SMC ● Usage Scene:Power plants, substations and other power places

Categories:

Cable Branch Box

Product Overview
Low-voltage cable branch box is widely used in cable distribution network system of cable engineering equipment, mainly power cables and box variable, load switch cabinet, negative a fused combination of electrical cabinet, ring network power supply unit and so on connected, play a tap, branching, relaying or conversion role for the cable network to provide great convenience.

Model Meaning
DFW-cable branch box

□-number of main circuits

□-Number of branch circuits

□ - Cabinet design serial number (A1, A2, B1, B2)

□- Rated current of main circuit

□-Program number

Functional Characteristics
SMC: SMC cable transfer box box body adopts SMC composite material (sheet molding plastic) molded at high temperature. It has light specific gravity, anti-seismic corrosion, aging resistance, good sealing performance, beautiful, all-weather protection function, can meet the needs of various harsh environments and places in the outdoor engineering projects, to overcome the outdoor metal cable branch box box easy to corrosion and short service life and poor thermal insulation and heat preservation performance and other defects.

Main technical parameters

No.

Item

Unit

Technical Parameters

1

Box

Structure type

 

Inlet line adopts disconnecting switch, outlet line adopts molded case circuit breaker.

Installation

 

Outdoor floor-standing type

Box material

 

304 stainless steel

Shell protection grade

 

IP44

Box size

 

 

2

Busbar

Rated operating voltage

V

400

Rated insulation voltage

V

690

Rated frequency

Hz

50

Rated current

A

160/250/400/630

Rated short-circuit withstand current 

 

10kA,1S

Busbar material

 

T2 electrical copper

3

Isolation switch

Number of poles

 

3P

Rated working voltage

V

400

Rated insulation voltage 

V

690

Rated current

A

160/250/400/630

Rated short-time withstand current 

 

10kA,1S

4

Plastic case circuit breaker

Number of poles

 

3P

Breaker type

 

Electronic type Configuration of three-stage protection function of the electronic release (long and short delay with the machine well motor start time length)

Rated operating voltage 

V

400

Rated insulation voltage

V

690

Rated current

A

250/160/400

Rated ultimate breaking capacity

kA

50

Rated operating breaking capacity

kA

35

Operating conditions

Name

Unit

Project demand value

Filth level

 

 III (indoor)/IV (outdoor)

Ambient temperature

Ambient temperature

-25℃~+40℃(indoor)

-25℃~+45℃(outdoor)

Maximum daily temperature difference

K

25

Hottest monthly average temperature 

30

Maximum annual average temperature

20

Humidity

Average daily relative humidity

%

≤95

Monthly average relative humidity

≤90

Elevation

M

≤1000

Solar radiation intensity

W/cm2

0.1

Earthquake resistance

Horizontal ground acceleration

m/s2

0.2g

Vertical ground acceleration

m/s2

0.15g

Sine resonance 3 cycles

 

≥1.67

Safety Factor

Installation place

Indoor/outdoor

Key words:

Cable branch box

Get A Quote

Leave your contact information and get a free product quote

Solution

Become a leader in the power distribution industry in the intelligent era

Related Products

The company mainly operates transformer and distribution equipment such as screens, desks, cabinets, and boxes, as well as transformer and distribution equipment, transformers, switches, automation control systems, etc

6.6\11kV Oil-immersed Transformer


● Voltage: 6kV to 11kV ● Capacity: 30kVA to 2500kVA

10kV Three-dimensional Rolled Iron Core Transformer


● Voltage: 400V, 6kV to 10kV ● Capacity: 30kVA to 2500kVA ● Model: S13、S20、S22

1250kVA Epoxy Resin Cast Dry Type Transformer


● Voltage: 10kV ● Capacity: 30kVA to 2500kVA ● Model: SC(B)10

630kVA Three Phase Oil Immersed Transformer 10kV


● Voltage: 400V/10kV ● Capacity: 30kVA to 2500kVA