Photovoltaic convergence box
+
  • Photovoltaic convergence box

Photovoltaic convergence box

● Material: stainless steel ● Product features: Good sealing, anti-corrosion and anti-rust, sturdy and durable

Categories:

Photovoltaic Combiner Box

Product Function
The convergence box in the photovoltaic power generation system is to ensure that the photovoltaic components are connected in an orderly manner and convergence function of the wiring device. The device can guarantee the PV system in the maintenance, inspection is easy to cut off the circuit, when the PV system failure to reduce the scope of power outages. 

The convergence box refers to the user can be a certain number of the same specifications of the PV battery in series, composed of a PV series, and then a number of PV series connected in parallel to the PV convergence box, in the PV convergence box convergence, through the controller, DC power distribution cabinet, PV inverter, AC distribution cabinet, supporting the use of a complete photovoltaic power generation system to achieve grid-connected with the utility power.

Product features

  1. Safety: equipped with AC circuit breakers of first-line brands at home and abroad and secondary AC lightning protection, with quick-break (magnetic detachment), overcurrent (thermal detachment) protection, with relative ground and phase-to-phase lightning protection.
  2. Reliable: unique bending type copper row structure technology patent, internal core devices through the CCC certification.
  3. Stable: the main circuit is designed with all copper rows.
  4. Sturdy: the box is made of cold rolled steel plate bending, box cover inside the reinforcement, the chassis as a whole is not deformed, and waterproof, rust-proof, sunscreen, easy to break through the IP65 protection level.
  5. Intelligent: The monitoring module adopts high-end MCU processor and current sensor, and uses ModBus-RTU communication protocol to realize local/remote data monitoring through RS485 communication interface.

Technical Parameters

Basic Parameters

Maximum input voltage

690VAC

Input current per circuit

0~100A

Maximum output current

200A/315A/400A/500A

Number of input channels

2/3/4/5

Number of output channels

1

Response time

<25ns

Rated Frequency

50HZ/60HZ

Enclosure

Case Material

Cold rolled steel/stainless steel/SMC

Protection class

IP65

Dimension

Customized

AC Surge Protector

Maximum working voltage(AC)

400V

Maximum Discharge Current(AC)

40KA

Molded Case Circuit Breaker

Rated voltage(AC)

690V

Rated current(AC)

According to customer's requirement

Environmental parameters

Operating temperature

﹣20℃—﹢60℃

Working humidity

90%%

Altitude

2000m (above 2000m load shedding)

Installation

Wall mounting

Key words:

Photovoltaic Grid Box

Get A Quote

Leave your contact information and get a free product quote

Solution

Become a leader in the power distribution industry in the intelligent era

Related Products

The company mainly operates transformer and distribution equipment such as screens, desks, cabinets, and boxes, as well as transformer and distribution equipment, transformers, switches, automation control systems, etc

1000kVA Oil-immersed Transformer


● Voltage: 6kV to 11kV ● Capacity: 30kVA to 2500kVA

10kV Distribution Transformer


● Voltage: 400V, 6kV to 10kV ● Capacity: 30kVA to 2500kVA ● Model: S13、S20、S22

1250kVA Epoxy Resin Cast Dry Type Transformer


● Voltage: 10kV ● Capacity: 30kVA to 2500kVA ● Model: SC(B)10

500kVA Three Phase Oil Immersed Transformer 10kV


● Voltage: 400V/10kV ● Capacity: 30kVA to 2500kVA