Selection and Configuration Technical Specifications of High Voltage Distribution Cabinets

Jul 14,2026

FONT

The technology for selection and configuration of high voltage distribution cabinets covers equipment classification, technical parameters, selection principles and installation requirements. It serves as an important reference for the selection, configuration and acceptance of high and low voltage distribution cabinets in power transformation and distribution projects for industrial & civil buildings, municipal facilities, power systems and other fields.

I. Classification of High Voltage Switchgears

1. Classification by Insulation Mode

Type

Characteristics

Application Scenarios

Air-insulated Type

Air insulation adopted except for three-position load switches; less susceptible to environmental impacts, simple structure, low cost and relatively large footprint

Conventional substations, sites with sufficient space

Gas-insulated Type

Live components sealed in gas-filled tank (SF₆, dry air, etc.); high IP protection class, maintenance-free, compact structure and high reliability

Space-limited sites, areas with harsh environmental conditions

Solid-insulated Type

Solid insulation technology applied for encapsulating vacuum interrupters and conductive circuits; environmentally friendly, small dimension and high safety

Sites with high environmental protection requirements

2. Classification by Structural Form

Type

Characteristics

Application Scenarios

Fixed Type

Electric components fixedly mounted; ample internal space, simple structure, low cost yet inconvenient maintenance

Small substations, sites without frequent operation

Withdrawable Type

Main components installed on trolleys; convenient maintenance, high reliability with relatively higher cost

Critical loads, sites requiring frequent maintenance

II. Main Technical Parameters of High Voltage Switchgears

1. Basic Parameter Requirements

  • Rated Voltage: 12kV, 24kV, 40.5kV
  • Rated Current: 630A, 1250A, 1600A, 2000A, 2500A, 3150A
  • Rated Short-time Withstand Current: 20kA, 25kA, 31.5kA, 40kA
  • Rated Peak Withstand Current: 50kA, 63kA, 80kA, 100kA
  • Rated Short-circuit Breaking Current: 20kA, 25kA, 31.5kA, 40kA

2. Reference Dimensions and Weight

Type

Width (mm)

Depth (mm)

Height (mm)

Weight (kg)

Fixed Switchgear

800–1000

1500–1800

2200–2300

600–800

Withdrawable Switchgear

800–1000

1500–1800

2200–2300

800–1200

Gas-insulated Switchgear

600–800

1200–1500

2000–2200

500–700

3. Selection Principles

  • Select corresponding switchgear type according to load characteristics 
  • Take space constraints of installation sites into consideration 
  • Reserve appropriate expansion capacity 
  • Meet operation and maintenance requirements 
  • Comply with environmental protection and energy-saving requirements

Get A Quote