The complete set of 10kV column station equipment is revised by the State Grid for the implementation of the requirements of the procurement work of 10kV column station complete set, further deepen and improve the typical design of distribution network engineering, and the State Grid Operation and Inspection Department on the basis of in-depth research and extensive consultation, and the organization of the revision. The company through the research and introduction of a new one-piece combination of compensation module, completely replaced the old composite switch + capacitor switching method, not only reduces the company's production costs, but also improves the production efficiency, so that the company in the State Grid bidding, more than a share of the advantage.

Technical parameters and application environment conditions

System voltage: 10kV on the high voltage side / 0.4kV on the low voltage side
System nominal voltage: 10kV;
Maximum operating voltage: 12kV;
Rated capacity: 50~400kVA
Compensation capacity: 30~200kvar
Rated frequency: 50Hz;
Filth level: e class;
Installation mode: ZA-1-CX, ZA-1-ZX, ZA-1-CL
Ambient temperature: Maximum daily temperature not exceeding +45℃, lower limit of daily temperature -25℃, maximum daily temperature difference 25, hottest monthly average temperature 30℃, maximum annual average temperature 20℃ (or provided by the customer);
Ice cover thickness: 20mm;
Altitude: no more than 1000m above sea level;
Solar radiation intensity: 0.1W/cm2;
Seismic tolerance: geomorphic horizontal acceleration 3 m/s2; sinusoidal resonance 3 cycles safety coefficient not less than 1.67;
The average maximum wind speed of 35m/s maintained for 10min at a height of 10m above the ground.

Key words:

10kV pole mounted transformer set

Get A Quote

Leave your contact information and get a free product quote

Solution

Become a leader in the power distribution industry in the intelligent era

Related Products

The company mainly operates transformer and distribution equipment such as screens, desks, cabinets, and boxes, as well as transformer and distribution equipment, transformers, switches, automation control systems, etc

1000kVA Oil-immersed Transformer


● Voltage: 6kV to 11kV ● Capacity: 30kVA to 2500kVA

10kV Distribution Transformer


● Voltage: 400V, 6kV to 10kV ● Capacity: 30kVA to 2500kVA ● Model: S13、S20、S22

1250kVA Epoxy Resin Cast Dry Type Transformer


● Voltage: 10kV ● Capacity: 30kVA to 2500kVA ● Model: SC(B)10

500kVA Three Phase Oil Immersed Transformer 10kV


● Voltage: 400V/10kV ● Capacity: 30kVA to 2500kVA